Аortic valve reconstruction with xenopericardium
Abstract
Aortic valve reconstructive surgeries using biomaterials at early stages were not widespread due to
the obtained results. However, due to the rapid development in the field of surgery and bioengineering technologies, there has been an increasing number of works devoted to the study of this
problem. The article presents an experimental data obtained in Russian Research Center of Surgery,
describing the basic techniques of the use of aortic leaflets from xenopericardium. This procedure
using the bioengineering designed native valves was introduced into clinical practice.
Keywords:aortic valve, aortic valve reconstruction, xenopericardium
Clin. Experiment. Surg. Petrovsky J. 2016. № 4. Р. 16–21.
Received: 15.10.2016. Accepted: 30.10.2016.
References
1. Barratt-Boyes B., Christie G. What is the best bioprosthetic
operation for the small aortic root? Allograft, autograft, porcine,
pericardial? Stented or unstented? J Card Surg. 1994; Vol. 9 (Suppl.
2): 158–64.
2. Duran C., Gometza B., Kumar N., Gallo R., et al. From aortic
cusp extension to valve replacement with stentless pericardium. Ann
Thorac Surg. 1995; Vol. 60: S428–S32.
3. Ozaki S., Kawase I., Yamashita H., Uchida S., et al. Aortic
valve reconstruction using autologous pericardium for aortic
stenosis. Circ. J. 2015; Vol. 79 (N 7): 1504–10.
4. Song M., Yang H., Choi J., Shin J., et al. Aortic valve
reconstruction with use of pericardial leaflets in adults with bicuspid
aortic valve disease: early and midterm outcomes // Tex. Heart Inst.
J. 2014. Vol. 41, N 6. P. 585–591.
5. Evseev E.P., Baikov V.V., Kevorkova R.A., Izotova E.M., Iva-
nov V.A. Replacement of aortal valve cusps using xenopericardium
in experiment. Kardiologiya i serdechno-sosudistaya khirurgiya
[Cardiology and Cardiovascular Surgery]. 2012; Vol. 5 (3): 66–7.
(in Russian)
6. Gasparyan V. Method of determination of aortic valve
parameters for its reconstruction with autopericardium: An
experimental study. J Thorac Cardiovasc Surg. 2000; Vol. 119 (N 2):
386–7.
7. Ivanov V.A., Evseev E.P., Domnin V.V., Fedulova S.V.
Replacement of single aortic valve cusp using xenopericardium.
Kardiologiya i serdechno-sosudistaya khirurgiya [Cardiology and
Cardiovascular Surgery]. 2012; Vol. 5 (3): 79–81. (in Russian)
8. Ross D. Surgical reconstruction of the aortic valve. Lancet.
1963; Vol. 281(N 7281): 571–4.
9. Bjork V., Hultquist G. Teflon and pericardial aortic valve
prosthesis. J Thorac Cardiovasc Surg. 1964; Vol. 47: 693–702.
10. Edwards W. Aortic valve replacement with autogenous
tissue. Ann Thorac Surg. 1969; Vol. 8 (N 2): 126–32.
11. Bahnson H., Hardesty R., Baker L., Brooks D., et al.
Fabrication and evaluation of tissue leaflets for aortic and mitral
valve replacement. Ann Surg. 1970; Vol. 171 (N 6): 939–47.
12. Yacoub M., Knight E., Towers M. Late results of mitral valve
replacement using «fresh» unstented aortic homografts. Thorac
Cardiovasc Surg. 1973; Vol. 21 (N 5): 458–64.
13. Batista R., Dobrianskij A., Comazzi M. Clinical experience
with stentless pericardial aortic monopatch for aortic valve
replacement. J Thorac Cardiovasc Surg. 1987; Vol. 93 (N 1): 19–26.
14. Ozaki S., Kawase I., Yamashita H., Uchida S., et al. A total
of 404 cases of aortic valve reconstruction with glutaraldehyde-
treated autologous pericardium. J Thorac Cardiovasc Surg. 2014;
Vol. 147 (N 1): 301–6.
15. Ozaki S., Kawase I., Yamashita H., Uchida S., et al.
Reconstruction of bicuspid aortic valve with autologous pericardium.
Circ J. 2014; Vol. 78 (N 5): 1144–51.
16. Rankin J., Nobauer C., Crooke P., Schreiber C., et al.
Techniques of autologous pericardial leaflet replacement for aortic
valve reconstruction. Ann Thorac Surg. 2014; Vol. 98 (N 2): 743–5.
17. Mazzitelli D., Stamm C., Rankin J., Pfeiffer S., et al. Leaflet
reconstructive techniques for aortic valve repair. Ann Thorac Surg.
2014; Vol. 98 (N 6): 2053–60.
18. Yaku H. Aortic valve reconstruction with autologous
glutaraldehyde-treated pericardium. Circ J. 2014; Vol. 78 (N 5):
1063–5.
19. Ozaki S., Kawase I., Yamashita H., Nozawa Y., et al. Aorticvalve
reconstruction using autologous pericardium for patients aged less than
60 years. J Thorac Cardiovasc Surg. 2014; Vol. 148 (N 3): 934–8.