Brain protection during transcatheter aortic valve implantation: clinical case study
Abstract
This article
describes transcatheter aortic valve implantation (TAVI) with and without the
brain embolism protection system (BPS). A clinical case study shows that the
use of the Sentinel TM CPS BPS prevented deterioration of the
neurophysiological status in the early postoperative period of TAVI. A
randomized prospective study is needed to evaluate the effect of BPS on a
relevant sample of patients.
Keywords: transcatheter aortic valve implantation; brain protection system; postoperative cognitive dysfunction; electroencephalography
Funding. The study was financially supported by the Ministry of Science and
Higher Education of the Russian Federation as part of the exploratory research
study “Endovascular, hybrid, extracorporeal technologies for the prevention and
treatment of heart and vascular pathology in cardiac surgery” No.
0419-2023-0002.
Conflict of
interest. The authors declare no conflict of interest.
For citation: Tarasova I.V., Tarasov R.S., Kupriyanova D.S., Sosnina A.C., Syrova
I.D., Trubnikova O.A., Ganyukov V.I. Brain protection during transcatheter
aortic valve implantation: clinical case study. Clinical and Experimental
Surgery. Petrovsky Journal. 2025; 13 (1): 120–6. DOI: https://doi.org/10.33029/2308-1198-2025-13-1-120-126 (in Russian)
References
- Abugov S.A., Saakyan Yu.M., Puretskiy M.V., Polyakov R.S., Mardanyan G.V., Pirkova A.A., et al. Safety and effectiveness of proctoring sessions in transcatheter aortic valve implantation using the example of the Russian Scientific Center of Surgery named after academician B.V. Petrovsky. Endovaskulyarnaya khirurgiya [Endovascular surgery]. 2018; 5 (3): 309–15. DOI: https://doi.org/10.24183/2409-4080-2018-5-3-309-315 (in Russian)
- Protopopov A.V., Ganyukov V.I., Tarasov R.S. Transcatheter interventions in heart valve pathology. Krasnoyarsk: Verso, 2021: 528 p. ISBN: 978-5-94285-214-6. (in Russian)
- Kroon H., von der Thusen J.H., Ziviello F., van Wiechen M., Ooms J.F.W., Kardys I., et al. Heterogeneity of debris captured by cerebral embolic protection filters during TAVI. EuroIntervention. 2021; 16 (14): 1141–7. DOI: https://doi.org/10.4244/EIJ-D-20-00744
- Kapadia S.R., Kodali S., Makkar R., Mehran R., Lazar R.M., Zivadinov R., et al.; SENTINEL Trial Investigators. Protection against cerebral embolism during transcatheter aortic valve replacement. J Am Coll Cardiol. 2017; 69 (4): 367–77. DOI: https://doi.org/10.1016/j.jacc.2016.10.023 Epub 2016 Nov 1. PMID: 27815101.
- Seeger J., Virmani R., Romero M., Gonska B., Rottbauer W., Wöhrle J. Significant differences in debris captured by the sentinel dual-filter cerebral embolic protection during transcatheter aortic valve replacement among different valve types. JACC Cardiovasc Interv. 2018; 11 (17): 1683–93. DOI: https://doi.org/10.1016/j.jcin.2018.06.018 Epub 2018 Aug 25. PMID: 30154060.
- Pollari F., Hitzl W., Vogt F., Cuomo M., Schwab J., Söhn C., et al. Aortic valve calcification as a risk factor for major complications and reduced survival after transcatheter replacement. J Cardiovasc Comput Tomogr. 2020; 14 (4): 307–13. DOI: https://doi.org/10.1016/j.jcct.2019.12.001
- Bjursten H., Koul S., Duvernoy O., Fagman E., Samano N., Nilsson J., et al. Calcium load in the aortic valve, aortic root, and left ventricular outflow tract and the risk for a periprocedural stroke. Struct Heart. 2022; 6 (4): 100070. DOI: https://doi.org/10.1016/j.shj.2022.100070
- Seeger J., Gonska B., Otto M., Rottbauer W., Wöhrle J. Cerebral embolic protection during transcatheter aortic valve replacement significantly reduces death and stroke compared with unprotected procedures. JACC Cardiovasc Interv. 2017; 10 (22): 2297–303. DOI: https://doi.org/10.1016/j.jcin.2017.06.037
- Harmouch W., Karnkowska B., Thakker R., Rasmussen P., Shalaby M., Khalife W., et al. Cerebral embolic protection in transcatheter aortic valve implantation using the sentinel cerebral protection system: a systematic review and meta-analysis. Cardiol Ther. 2024; 13 (2): 299–314. DOI: https://doi.org/10.1007/s40119-024-00359-4
- Tarasova I.V., Tarasov R.S., Trubnikova O.A., Ganyukov V.I. Methodical approach to assessing the neurophysiological status of patients who underwent transcatheter aortic valve implantation. Kompleksnye problemy serdechno-sosudistykh zabolevaniy [Complex Problems of Cardiovascular Diseases]. 2022; 11 (2): 6–17. DOI: https://doi.org/10.17802/2306-1278-2022-11-2-6-16 (in Russian)
- Tarasova I., Kukhareva I., Kupriyanova D., Temnikova T., Gorbatovskaya E., Trubnikova O. Electrical activity changes and neurovascular unit markers in the brains of patients after cardiac surgery: effects of multi-task cognitive training. 2024; 12 (4): 756. DOI: https://doi.org/10.3390/biomedicines12040756